Multi-Circuit Extrusion Temperature Control Unit
Temp Control Range: +25℃
+120℃
Circulation Configuration: 3 or 4 Circuits
Heating Capacity: 4 kW per Set
Maximum Operating Temperature: 120°C
Temperature Control Accuracy: PID ±1°C
Custom Configurations Available
How Multi-Circuit Extrusion Temperature Control Units Work
The AEXT and AEXF bring multiple heating and circulation assemblies into a common equipment cabinet.
This configuration provides an alternative to distributing separate temperature controllers throughout the machinery.
With a multi-circuit temperature controller, equipment selection extends beyond sizing an individual heater and pump. The circulation requirements of several processing sections must be organized within a coordinated machine layout, taking their thermal relationships and connection requirements into account.
Configure Temperature Control Across Your Processing Sections
Submit your circuit layout for a configuration review.
Multi-Circuit Equipment Architecture and Connections

Integrated Heating and Circulation Assemblies
Multiple heating and pump assemblies are housed within one equipment cabinet, creating a centralized location for circulation hardware serving compatible processing sections. This arrangement simplifies equipment allocation during machine layout planning, with installation and servicing access considered as part of the overall configuration.

Repeated Component Capacity
Both AEXT and AEXF use identical standard heating and pump motor ratings across their respective component sets. Capacity expansion is achieved by adding another assembly rather than increasing the output of an existing heating or pump component. This configuration is particularly relevant to machinery with comparable thermal requirements at several processing positions.

Grouped Water Circulation Connections
Multiple 3/4-inch circulation connection groups correspond to the equipment’s heating and pump arrangements. These connections provide defined interfaces between the temperature controller and the associated processing components, supporting organized supply and return piping within the production line.

Equipment Operation and Control Integration
Direct cooling, heating power switching, automatic startup venting, return water temperature display, and fault indications support daily equipment operation. Optional PLC control and RS485 communication configurations are available to accommodate compatible extrusion machinery control requirements.
Review Your Multi-Circuit Equipment Configuration
Our team can assess the circuit arrangement required by your machinery.
AEXT-10 and AEXF-10 Technical Specifications
| ITEM | UNIT | AEXT-10 | AEXF-10 |
| Maximum Operating Temperature | °C | 120 | 120 |
| Temperature Control Accuracy | °C | ±1 | ±1 |
| Heating and Pump Sets | — | 3 | 4 |
| Heating Capacity | kW | 4 × 3 | 4 × 4 |
| Total Rated Heating Capacity | kW | 12 | 16 |
| Pump Motor Power | kW | 0.75 × 3 | 0.75 × 4 |
| Pump Head | m | 22 | 22 |
| Cooling Water Connection | inch | 3/4 | 1 |
| Circulation Connection | inch | 3/4 × 3 | 3/4 × 4 |
| Dimensions (L × W × H) | mm | 800 × 900 × 1000 | 800 × 1200 × 1000 |
| Temperature Regulation | / | PID | |
| Heat Transfer Medium | / | Water | |
| Cooling Method | / | Direct Cooling | |
| Power Supply | / | AC 3N, 380/480 V, 50 Hz | |
| Alarm Functions | / | Pump Reversal, Water Shortage, Excess Temperature, Overload | |
| Optional Control Functions | / | PLC Control, RS485 Communication | |
| Optional Operating Functions | / | Rapid Cooling Startup, Blowback Water Return | |
Integrated Multi-Circuit Equipment vs. Separate Temperature Controllers
Compare Multi-Circuit Equipment Configurations
Request a quotation for an AEXT-10 or AEXF-10 configuration.
How Many Temperature Control Circuits Does Your Extrusion Line Need?
01. Divide the Process into Thermal Circuits
Map the processing sections that require liquid temperature regulation: components with compatible thermal conditions may share a circulation arrangement, while others need dedicated hardware. Establish the required circuit layout before choosing between the three-set AEXT and four-set AEXF configurations.
02. Allocate Heating and Pump Capacity to Each Circuit
Evaluate each processing section's thermal load and circulation requirements separately—even on one line, a forming component's energy demand can differ substantially from a downstream roll's heat removal demand. Do not use the combined heating capacity of a multi-circuit unit as the sole criterion: each circuit set must be sized for its section, and a customized configuration may be needed where requirements differ considerably.
03. Determine the Required Control Relationships
Identify which sections run at common temperatures and which need separately adjustable setpoints, and whether the process requires individual monitoring, alarm reporting, or selective circuit operation. Multiple heating and pump assemblies define the physical circulation arrangement, but the degree of independent temperature regulation must be confirmed through the selected control architecture.
04. Coordinate Piping, Utilities, and Equipment Access
Centralized placement brings several water connections to one location, so review pipe routing between the controller and each processing section with sufficient access for installation and servicing. Ensure the electrical supply and cooling water availability can also accommodate the connected sections' expected simultaneous operating demand.
Your circuit layout, individual thermal requirements, control relationships, and installation drawings provide the basis for selecting an AEXT or AEXF configuration. These details help us assess the complete equipment arrangement before manufacturing.
Multi-Roll and Multi-Stage Processing Applications
Three-Roll Sheet Extrusion
Cast Film Processing
Multi-Roll Calendering
Extrusion Coating and Laminating Lines

A three-roll forming assembly brings the extruded sheet into successive contact with several roll surfaces. Thermal conditions at each contact point can influence material forming and surface characteristics. Where all three rolls require dedicated water circulation, the AEXT provides a relevant equipment configuration for further capacity assessment.

The primary chill roll and subsequent processing rolls may perform different heat transfer functions along a cast film line. Their thermal loads should be assessed individually when several water-controlled components are incorporated into the downstream equipment. Appropriate circuit allocation helps match temperature control capacity to these different processing functions.

Successive roll gaps progressively shape the material during calendering. Roll temperature influences material deformation and processing conditions at each stage. A multi-circuit configuration can serve compatible water-controlled roll assemblies requiring several sets of heating and circulation hardware.

Forming, coating, bonding, and cooling operations may be combined within one continuous production process. An integrated extrusion roll temperature control system can be evaluated according to the number and thermal requirements of the liquid-controlled components serving these different functions.
Custom Multi-Circuit Extrusion Temperature Control Unit
When specifying several circulation circuits, the capacity required by one processing section may differ from that of the next. We assess these requirements individually, including heating output, pump motor capacity, and equipment integration. AODE’s custom multi-circuit temperature control units can be configured according to the technically feasible heating and circulation combinations established for your machinery.
Related Industrial Temperature Control Units
FAQ
What technical information is required for an AEXT or AEXF quotation?
Provide the number of temperature-controlled sections, operating temperature and required capacity of each circuit, equipment layout, electrical supply, and cooling water conditions. Include any separate regulation or communication requirements, together with purchase quantity and delivery destination, so our team can confirm equipment specifications, pricing, technical documentation, and lead time.
Can AODE customize different heating and pump capacities within one cabinet?
AODE offers customized heating power and pump motor capacity. Where processing sections have unequal thermal or circulation requirements, we assess each circuit individually to determine whether different capacity combinations can be integrated into the same equipment configuration.
Can several circuits use a common cooling water supply?
A common external cooling water supply may support multiple circulation arrangements, subject to the equipment's internal cooling configuration. Available water temperature, supply pressure, and simultaneous cooling demand must be evaluated to ensure that the utility can accommodate the connected processing sections.
When is an integrated multi-circuit unit preferable to several separate controllers?
An integrated unit is particularly relevant when several processing components can be served from a common equipment location. Separate controllers offer more flexibility where individual sections require different standard equipment capacities or distributed installation. The decision should also account for piping arrangements, control requirements, and maintenance access.
How is the circulation flow of a multi-circuit temperature controller determined?
Circulation requirements should be evaluated for each connected processing section. Pump performance, channel resistance, and the selected hydraulic configuration determine the actual working flow. Confirm whether published pump ratings apply to individual component sets or the complete unit before calculating combined circulation capacity.
Can the total heating capacity be transferred to one circulation circuit?
No. The standard AEXT-10 and AEXF-10 configurations consist of individual 4 kW heating sets. Their combined ratings of 12 and 16 kW do not represent the heating power available to a single circulation circuit. A processing section requiring greater heater output needs a separately assessed configuration.
Can unused circulation sets be switched off individually?
Selective circuit operation depends on the installed control architecture. If your machinery operates with different numbers of active processing sections, confirm the required start, stop, and standby functions during equipment specification.
Can each circuit of the AEXT or AEXF operate at a different temperature?
Multiple heating and pump assemblies do not automatically establish independently adjustable temperature regulation. The control configuration determines whether different setpoints can be assigned to individual circuits. Specify the required operating temperatures and regulation functions of each processing section when ordering.