Dual-Circuit Mold Temperature Controller

Dual-Circuit Mold Temperature Controller

Temp Control Range: +25℃ +100℃

The AWMD-10 is a dual-circuit mold temperature controller that integrates two 9 kW heating sets and two circulation pumps into one cabinet. Designed for injection molds requiring separate water circuits, it offers PID temperature regulation up to 100°C.

Key Highlights:

Temperature Control Accuracy: PID ±1°C

Maximum Operating Temperature: 100°C

Heating Capacity: 6–18 kW

Direct Cooling & Automatic Air Venting

Custom Configurations Available

Request a Quote

How Dual-Circuit Mold Temperature Controllers Work

A mold with two separate water circuits does not always need two separate temperature controllers. The AWMD-10 combines dedicated heating and pumping components in a single cabinet, offering an alternative equipment layout for molds with multiple circulation requirements.

With grouped water connections and an integrated cabinet measuring 800 × 420 × 750 mm, our dual-circuit temperature control unit allows you to plan equipment placement and hose routing around the mold's existing water circuit design.

The principal advantage of the AWMD-10 lies in its circulation arrangement rather than higher temperature accuracy. For tooling that requires only one water circuit, the standard AWM series remains a simpler equipment option.

AODE AWMD-10 dual-circuit water temperature controller

Consolidate Two Mold Circuits into One Equipment Configuration

Contact AODE for a customized injection molding temperature control solution.

Request a Quote

AWMD-10 Heating and Circulation Features

The AWMD-10 brings together two independent heating and circulation sets within one cabinet, along with the control and protection functions needed for daily mold temperature management.
AWMD-10 heating and circulation feature 1
1

Dedicated Heating for Each Circuit

Heating capacity is divided between two 9 kW heating sets rather than supplied by a single 18 kW heater. Each connected water circuit must therefore be evaluated according to its own thermal demand, particularly when different mold sections require unequal amounts of heat.

AWMD-10 heating and circulation feature 2
2

Two-Pump Water Circulation

Differences in channel diameter, hose length, and internal resistance can result in unequal water distribution when several passages share one pump. The AWMD-10 incorporates two circulation pumps, providing dedicated pumping hardware for the two connected water paths.

AWMD-10 heating and circulation feature 3
3

Grouped Mold Water Connections

Two groups of four 3/8-inch circulation connections organize the equipment around a dual-circuit layout. This defined connection arrangement helps simplify hose routing and installation planning for molds with separately arranged water passages.

AWMD-10 heating and circulation feature 4
4

Integrated Heating, Cooling, and Protection

PID regulation adjusts temperature in response to sensor feedback, while direct cooling removes excess process heat. Automatic air venting assists during startup, and bypass protection and fault indications help operators recognize abnormal circulation or equipment conditions.

Review AWMD-10 Circuit and Connection Details

Contact AODE for a customized injection molding temperature control solution.

Request a Quote

AWMD-10 Mold Temperature Controller Specifications

The AWMD-10 integrates two heating and circulation sets in one cabinet. Review the per-circuit heating, pump performance, and connection specifications below to confirm that the equipment matches your mold water circuits.
ParameterSpecification
ModelAWMD-10
Maximum Operating Temperature100°C
Temperature Control Accuracy±1°C
Temperature RegulationPID
Heat Transfer MediumWater
Cooling MethodDirect Cooling
Circuit ConfigurationDual Circuit
Heating Capacity9 kW × 2
Total Rated Heating Capacity18 kW
Pump Motor Power0.75 kW × 2
Pump Flow100 L/min × 2
Pump Head16 m
Maximum Power Consumption19.5 kW
Power SupplyAC 3N, 380/400 V, 50 Hz
Cooling Water Connection1/2 inch
Circulation Connection(3/8 inch × 4) × 2
Alarm FunctionsPump Reversal, Water Shortage, Motor Overload
Dimensions (L × W × H)800 × 420 × 750 mm

AWMD-10 vs. Two Single-Circuit AWM-10(A) Controllers

One AWMD-10 integrates two heating and circulation sets in a single cabinet, matching the 18 kW total heating capacity and 1.5 kW total pump power of two separate AWM-10(A) units while occupying approximately 10.3% less nominal floor area. Both configurations share the same 100°C maximum operating temperature and ±1°C control accuracy. Actual installation space also depends on equipment clearances, hose routing, utility connections, and maintenance access.

Compare Equipment Configurations and Pricing

Request technical specifications and commercial pricing for your selected equipment.

Request a Quote

When Do You Need a Dual-Circuit Mold Temperature Controller?

Multiple mold water connections do not automatically require a dual-circuit controller. The decision should reflect how the water passages are organized, how much heat each section requires, and whether an integrated equipment arrangement suits your production layout.
01

01. Mold Water Circuit Layout

Review the mold's water circuit diagram before selecting equipment. Several parallel channels connected to a common manifold may operate with one circulation pump. Tooling designed around two dedicated supply and return paths, however, may require separate circulation hardware.

02

02. Thermal Requirements of Individual Circuits

Different mold sections may experience unequal heat transfer conditions because of geometry, material distribution, or contact with molten plastic. Determine the required operating temperature and thermal load of each section. If separate temperature setpoints are essential, verify the controller's independent regulation capability before ordering.

03

03. Heating and Pump Capacity per Circuit

The AWMD-10's total heating capacity should not be used to size an individual water circuit. Calculate the heating demand, required working flow, and pressure loss separately for each connected section. Both circuits must operate within the capabilities of their respective heating and pumping components.

04

04. One Integrated Unit or Two Separate Controllers

An integrated dual-circuit machine reduces the number of equipment cabinets that must be accommodated beside the molding machine. Two separate controllers, on the other hand, may offer greater flexibility when equipment needs to be relocated or assigned to different production lines. Compare installation space, utility requirements, and servicing arrangements before making your decision.

Dual-Circuit Mold Temperature Control Applications

The AWMD-10 is suited to consideration for injection molding equipment with two dedicated water circulation paths. Its application depends on the mold structure, required thermal conditions, and hydraulic characteristics of each connected section.
  • Fixed and Moving Mold Halves

  • Two-Component Injection Molding

  • Core and Cavity Temperature Management

  • Multi-Cavity Mold Groups

AODE dual-circuit mold temperature controller application

The fixed and moving halves of an injection mold can have different cooling channel arrangements and thermal characteristics. Separate circulation hardware offers an equipment option for tooling designed with dedicated water connections on each side.

AODE dual-circuit mold temperature controller application

Different polymers and molding stages may require distinct thermal conditions to achieve suitable bonding, filling, and dimensional characteristics. Where the tooling incorporates two liquid circulation paths, a dual-circuit water temperature controller can be evaluated against the requirements of each forming section.

AODE dual-circuit mold temperature controller application

Deep mold cores can retain heat differently from surrounding cavity surfaces, particularly in complex or relatively thick-walled components. Tooling equipped with dedicated core and cavity circuits can benefit from circulation arrangements matched to their respective heat transfer requirements.

AODE dual-circuit mold temperature controller application

Differences in channel length and hydraulic resistance can influence the distribution of water between cavity groups. Dedicated circulation pumps provide an alternative to supplying all passages through one common pump, although appropriate branch balancing remains necessary.

FAQ

Does AODE supply AWMD-10 controllers for OEM equipment integration and distribution?

Yes. We supply dual-circuit temperature control equipment for machinery integration and international distribution. Available product catalogs, technical specifications, and equipment connection information can support your purchasing and integration decisions.

How can I obtain AWMD-10 pricing, MOQ, and lead time?

Provide your purchase quantity, electrical requirements, intended application, and delivery destination. For the standard AWMD-10, our sales team can confirm equipment pricing, minimum order requirements, availability, production lead time, and shipping arrangements.

What maintenance does a dual-circuit temperature control unit require?

Both circulation paths should be inspected regularly for leakage, water contamination, and abnormal pump operation. Maintenance should address each set of hydraulic components rather than relying solely on the overall equipment status. Follow the operating manual for inspection intervals, safe isolation, and servicing procedures.

What should I check if one circuit has insufficient water flow?

Begin by checking for restricted hoses, blocked mold passages, trapped air, or closed valves in the affected circuit. A circulation problem in one water path does not necessarily indicate insufficient capacity throughout the entire machine. Qualified personnel should inspect the relevant hydraulic components according to the equipment instructions.

Can the two circuits have different heating capacities?

The standard AWMD-10 contains two 9 kW heating sets. If one water circuit requires greater heating output than the other, submit the individual thermal requirements to AODE. We can assess whether a non-standard heating configuration is technically feasible.

Can a dual-circuit controller serve two separate molds?

It may be suitable when both molds have compatible operating temperatures, circulation connections, and heating requirements. The control arrangement must also support the intended production conditions, particularly if the molds operate on different schedules or require separate temperature settings.

Is the combined pump flow of 200 L/min available to one circuit?

No. The published 100 L/min × 2 rating represents two circulation pumps rather than one pump rated at 200 L/min. Each circuit's actual working flow is determined by its hydraulic resistance and the applicable pump performance curve.

Can the AWMD-10 maintain two different temperature setpoints?

The AWMD-10 incorporates two sets of heating and circulation components. However, independently adjustable temperatures require suitable sensing and control functions for each circuit. If your mold requires two different setpoints, confirm the applicable control configuration with our technical team before purchasing.