TCU Glycol Water Series

TCU Glycol Water Series

-40 1766802737646@1x-(1).webp +140℃

Features

The use of heat exchangers for hot and cold heat transfer, the use of high and low temperature heat source for heat transfer and temperature control, you can achieve a wide temperature range, can achieve -40 ~ 140 ℃ full range of temperature control .

Customised design of temperature control system for different cold and heat sources.

Built-in electric heater for auxiliary heating, so that the TCU temperature control system can reach a higher design temperature; the maximum design temperature can reach 200 ℃, the operating temperature of 180 ℃.

Request a Quote

Product Specifications

TEMUNITARDJ-20ARDJ-50ARDJ-75
Temp control accuracyPID±1℃
Powersupply/3P AC380V/480V 50HZ(3phase+Earth)
Heattransfer medium/Glycolaqueoussolution
Cooling method/Indirect cooling(chilled water/cooling water)
Heating method/Indirect heating(steam/high-temperature thermal oil/direct heating
Pump Horsepowerhp25.07.5
PumpflowL/min200300533
Pumpheadm203050
Max.power consumptionKW1.545.5
Cooling waterpipeinch1.5"2"3"
Circulating water pipeinch1.5"2"3"
Expansion tankvolumeL100200500