TCU Glycol Water Series
-40℃
+140℃
The use of heat exchangers for hot and cold heat transfer, the use of high and low temperature heat source for heat transfer and temperature control, you can achieve a wide temperature range, can achieve -40 ~ 140 ℃ full range of temperature control .
Customised design of temperature control system for different cold and heat sources.
Built-in electric heater for auxiliary heating, so that the TCU temperature control system can reach a higher design temperature; the maximum design temperature can reach 200 ℃, the operating temperature of 180 ℃.
Product Specifications
| TEM | UNIT | ARDJ-20 | ARDJ-50 | ARDJ-75 |
| Temp control accuracy | ℃ | PID±1℃ | ||
| Powersupply | / | 3P AC380V/480V 50HZ(3phase+Earth) | ||
| Heattransfer medium | / | Glycolaqueoussolution | ||
| Cooling method | / | Indirect cooling(chilled water/cooling water) | ||
| Heating method | / | Indirect heating(steam/high-temperature thermal oil/direct heating | ||
| Pump Horsepower | hp | 2 | 5.0 | 7.5 |
| Pumpflow | L/min | 200 | 300 | 533 |
| Pumphead | m | 20 | 30 | 50 |
| Max.power consumption | KW | 1.5 | 4 | 5.5 |
| Cooling waterpipe | inch | 1.5" | 2" | 3" |
| Circulating water pipe | inch | 1.5" | 2" | 3" |
| Expansion tankvolume | L | 100 | 200 | 500 |