Standard Water Mold Temperature Controller
Temp Control Range: +25℃
+100℃
Temperature Control Accuracy: PID ±1°C
Maximum Operating Temperature: 100°C
Heating Capacity: 6–18 kW
Direct Cooling & Automatic Air Venting
Water Temperature Control Unit for Industrial Processing
AODE's standard water mold temperature controller regulates process temperature by circulating heated water through connected molds or equipment circuits. The AWM series is primarily used for mold temperature management in injection molding, while its water-based heating principle can also serve other industrial applications within the equipment's operating limits.
The available models differ in heating capacity, pump flow, and circulation connections, allowing customers to select equipment according to their thermal load and hydraulic requirements. Return water temperature display and automatic air venting during startup make it easier for operators to prepare and monitor the circulation system.
Heating power switching, a bypass pressure relief circuit, and fault indication provide practical support for routine operation. When standard specifications do not meet the application requirements, AODE can review the process conditions and provide customized temperature control equipment.
Looking for a Standard Water Mold Temperature Controller?
Contact AODE for a customized water mold temperature control solution.
Key Features of AODE's Water Type Mold Temperature Controller
Practical heating, circulation, and equipment protection functions for daily industrial temperature management.
PID Temperature Regulation & Direct Cooling
The microcomputer-based controller manages heating and direct cooling to regulate circulating water temperature. With a specified PID ±1°C control accuracy, the system supports temperature management within the selected model's operating range.
Return Water Display & Automatic Air Venting
Return water temperature is displayed for routine monitoring, while the automatic air venting function helps remove trapped air during startup. Operators can check water circuit conditions before bringing the connected equipment into normal production.
Bypass Pressure Relief & Fault Protection
The integrated bypass circuit provides pressure relief within the circulation system. Fault indication for water shortage, pump reversal, and overload helps operators identify abnormal equipment conditions and take appropriate action.
Heating & Circulation Configuration Options
Different AWM models provide varying heating capacities, pump performance, and water connections, including a dual-circuit model. AODE can evaluate equipment configuration requirements according to the customer's actual manufacturing process.
Need These Functions in Your Water Temperature Control Process?
Contact AODE for a customized water mold temperature control solution.
Standard Water Temperature Controller Specifications
| ITEM | UNIT | AWM-05(A) | AWM-10(A) | AWM-20 | AWMD-10 |
| Temp control range | ℃ | Inlet water temperature +25℃~100℃ | |||
| Temp control accuracy | ℃ | PID±1℃ | |||
| Power supply | / | AC 3N-380/400V-50HZ | |||
| Heat transfer medium | / | Water | |||
| Cooling method | / | Direct cooling | |||
| Heating capacity | KW | 6 | 9 | 12 | 9+9 |
| Motor power | KW | 0.37 | 0.75 | 1.5 | 0.75+0.75 |
| Pump flow | L/min | 26 | 100/33 | 150 | 100+100 |
| Pump head | m | 15 | 16/20 | 18 | 16 |
| Max.power consumption | KW | 6.37 | 9.75 | 13.5 | 19.5 |
| Alarm function | / | Pump reversal/Water shortage/Overload | |||
| Cooling water pipe | inch | 1/2 | 1/2 | 1/2 | 1/2 |
| Circulating water pipe | inch | 3/8*2 | 3/8*4 | 1 | (3/8*4)*2 |
| Size(L×W×H) | mm | 650*288*645 | 650*288*645 | 650*288*645 | 800*420*750 |
Not Sure Which AWM Model Fits Your Requirements?
Contact AODE for a customized water mold temperature control solution.
Water Mold Temperature Controller Applications
From household appliance housings to industrial plastic fittings, AODE's standard water mold temperature controller supports routine injection molding processes with different mold structures, part geometries, and production requirements.
Household Appliance Housings
Plastic Caps & Closures
Automotive Plastic Clips & Brackets
Industrial Plastic Fittings & Enclosures
Refrigerator interior panels, washing machine covers, and appliance control housings often feature large surfaces, ribs, and fastening structures. Uneven mold temperatures can contribute to warpage, sink marks, or inconsistent shrinkage across these features. AODE's standard water temperature control unit circulates heated water through compatible mold circuits to help maintain consistent thermal conditions during production.
Bottle caps and threaded closures are commonly produced in multi-cavity injection molds, where cavity-to-cavity consistency is important for dimensions and sealing performance. Temperature differences across the mold can affect shrinkage and thread formation. A properly selected water mold temperature controller helps manage the mold's thermal conditions during repeated, high-volume molding cycles.
Automotive clips, mounting brackets, and cable holders may contain snap-fit features, thin sections, and dimensional tolerances that affect assembly. During molding, changes in temperature can influence shrinkage and the fit of functional features. The AWM series provides controlled water heating and direct cooling to support repeatable molding conditions for suitable thermoplastic components.
Plastic pipe fittings, protective covers, and equipment enclosures can include thick-to-thin wall transitions, bosses, and internal ribs. These geometric differences influence cooling and shrinkage during injection molding. AODE's water type mold temperature controller provides circulating water temperature regulation to help manufacturers manage molding conditions for functional plastic parts.
Tell Us About Your Injection Molding Application
Contact AODE for a customized water mold temperature control solution.
AODE Industrial Water Temperature Control Projects
Case Study 1
Case Study 2
Case Study 3
Related Water Temperature Control Units
FAQ
What happens if the mold temperature is unstable during continuous production?
Temperature fluctuations during continuous production can affect plastic shrinkage, surface finish, and dimensional consistency. Changes in production cycles, mold heat load, and water circulation conditions may all contribute to unstable mold temperatures.
AODE's standard water mold temperature controller uses PID temperature regulation with a specified accuracy of ±1°C to manage circulating water temperature. Operators can also check return water temperature to assess operating conditions. If fluctuations continue, the mold circuit, heating capacity, and cooling water supply should be reviewed to identify the cause.
Why is the actual mold temperature different from the controller's set temperature?
The controller's set temperature refers to the temperature target at its control sensor, which may not match the temperature measured at the mold surface. Heat loss through hoses, mold channel layout, circulation flow, and heat transfer from the process can all affect the difference.
AODE's standard water temperature control unit provides return water temperature display to help operators monitor the circulation system. For applications requiring closer temperature verification, measure the mold at suitable locations and review the water circuit conditions rather than relying on the setpoint alone.
What should I check if water flow through the mold is too low?
Low circulation flow may result from blocked mold channels, restricted hoses, incorrectly positioned valves, trapped air, or excessive pressure loss. Even when a pump operates normally, the actual flow through the mold may be lower than its rated maximum flow.
Check that the circuit is correctly connected and that the required valves are open. AODE's standard water type mold temperature controller includes automatic air venting at startup, which helps remove trapped air from the circulation system. If the problem continues, stop the unit safely and have qualified personnel inspect the circuit before restarting production.
Why is my water temperature controller not cooling down properly?
First, check whether the external cooling water supply has sufficient flow and pressure and whether its temperature is low enough for the intended process. Restricted circulation, incorrect valve operation, or problems with the cooling control system may prevent the equipment from reducing the circulating water temperature as expected.
AODE's AWM series uses direct cooling, so its cooling performance depends on the available cooling water and operating conditions. If the issue persists, qualified technicians should inspect the cooling circuit and control components after safely isolating the equipment.
Can a water temperature control unit replace an industrial chiller?
Not in every application. A standard water temperature control unit regulates the temperature of circulating water through heating and direct cooling, but it does not provide the same independent refrigeration function as an industrial chiller.
If a process requires cooling water below the available supply temperature, an industrial chiller may be necessary. In some production systems, a chiller supplies cooling water while a temperature controller regulates the water circulating through the mold or processing equipment. The suitable arrangement depends on the required temperature and cooling load.
How do I select the right AODE standard water temperature controller model?
Start with the required operating temperature, estimated heating load, circulation flow, pump head, and available site utilities. AODE's AWM range includes models with different heating capacities, pump flow ratings, and water connection arrangements, including a dual-circuit configuration.
Customers should provide their mold or equipment type, operating conditions, circuit requirements, and power supply details. AODE can review these specifications and recommend a suitable standard model or customized temperature control equipment based on the actual process.